RailCorp Engineering Manual — Signals — Equipment Manual
Cerberus Level Crossing Monitor Field Equipment Manual TMG E1261
or as a Boolean expression
C = A & B
C will only be true when both A and B are true.
6.1.2.7.2 OR Operator
The logical OR operation is represented by the "+" character.
Examples of logical OR operations are as follows:
Either as relay logic by:
or as a Boolean expression
C = A + B
C will be true when either A or B are true.
6.1.2.7.3 NOT Operator
The logical NOT operation is represented by the "!" character.
Examples of logical NOT operations are as follows:
Either as relay logic by:
or as a Boolean expression by:
C = !A
C will be true when A is not true.